SCIENTIFIC RESEARCH

Your location:
Home page
>
Scientific research equipment
Page view:

winner 2309 Laser particle size analyzer

Model:Winner2309A

Use:The particle size testing of solid particles

Range of measurements:Wet method 0.01-2000μm;dry method 0.1-2000μm

Repeatable error:<1%(Test national standard sample D50 value)

Accuracy error:<±1%(Test national standard sample D50 value)

Decentralized approach:Wet method:Ultrasonic dispersion;Mechanical mixing dispersion;Electromagnetic pump cycle dispersion; Dry method: Compressed air turbulence dispersion

 

winner 319 Laser particle size analyzer

Model:Winer319(B)

Use:The particle size testing of spray droplets particles

Range of measurements:1-1000μm

Repeatable error:<1%(Test national standard sample D50 value)

Accuracy error:<1%(Test national standard sample D50 value)

 

winner 3003 Laser particle size analyzer

Model:Winner3003

Use:The particle size testing of solid particles

Range of measurements:Dry method 0.1-300μm

Repeatable error:<1%(Test national standard sample D50 value)

Accuracy error:<±1%(Test national standard sample D50 value)

Decentralized approach:Dry method:compressed air turbulence dispersion

 

Winner 311XP Spray laser particle size analyzer

Model:Winner311XP

Use:The particle size testing of spray droplets particles

Range of measurements:1-100μm

Repeatable error:<1%(Test national standard sample D50 value)

Accuracy error:<1%(Test national standard sample D50 value)

 

 

Rotor flowmeter

Model:LZB-4     Measurement range(gas):16-400L/h       working pressure(MPa):≤1

Model:LZB-6     Measurement range(gas):40-1000L/h      working pressure(MPa):≤1

Model:LZB-10    Measurement range(gas):100-2500L/h     working pressure(MPa):≤1

Model:LZB-15    Measurement range(gas):250-6000L/h     working pressure(MPa):≤0.6

Model:LZB-25    Measurement range(gas):1-25 /h       working pressure(MPa):≤0.6

Model:LZB-40    Measurement range(gas):4-60m³/h  working pressure(MPa):≤0.4

Model:LZB-50    Measurement range(gas):10-160m³/h      working pressure(MPa):≤0.4

Model:LZB-80    Measurement range(gas):50-400m³/h      working pressure(MPa):≤0.4

Model:LZB-100   Measurement range(gas):120-1000m³/h    working pressure(MPa):≤0.4

 

 

Monty constant temperature and humidity system

Equipment includes: desiccant wheel, recycled air, regenerative heater, table cooler 1, table cooler 2, reheater, humidifier, primary and intermediate filtration.
Desiccant wheel: Type of wheel-high efficiency titanium silicone gel; Drive form-belt; Dehumidification-2.3 kg/hr; Treatment of lateral pressure drop-284Pa; Regenerated lateral pressure drop-401 Pa
Renewable air: total wind volume of the system-99 M2 / HR; Fan speed-2850 rpm; Effective afterpressure-200 Pa
Regenerated heater: Heating type-electricity
Table cooler 1: handling wind volume-300 M2 / HR; Air intake parameters dry ball temperature-40.0-degC; Wet content-49.1-g/kg; Enthalpy-166.8-kj/kg; Air outlet parameters dry ball temperature-40.0-degC; Wet content-49.1-g/kg; Enthalpy-166.8-kj/kg; Row number-10; Air resistance-300 Pa
Table cooler 2: handling wind volume-300 M2 / HR; Refrigerated water flow-0.1 L/s; Air intake parameters dry ball temperature-39.0-degC; Wet content-3.2-g/kg; <UNK> -47.6-kj/kg; Air outlet parameters dry ball temperature-17.0-degC; Wet content-3.2-g/kg; Enthalpy-25.3-kj/kg; Row-6; Air resistance-180 Pa
Reheater: Treatment of air volume-300 M2 / HR; Air intake parameters dry ball temperature-10-degC; Air outlet parameters dry ball temperature-80-degC; Air resistance-50 Pa
Humidifier: Type-Electric heat; Humidification-12 kg/hr
Initial filtering: Model-G4; Resistance-100Pa; Efficiency-30 %
Medium effect filtration: Model-F9; Resistance-200 Pa; Efficiency-85 %